ALFA LAVAL MIB 303 FUEL SEPERATOR

START UP;
Starter;
·         Turn the black and red main switch on the control cabinet to the ‘’1 ON’’ position.
·         Turn both the start buttons to position ‘’1’’ to power up the control system.
For purifying only;
·         Close the bottom valve on the funnel,if open,and fill the funnel with water.
·         When the seperator has reached full speed connect the funnel to the quick-coupling on the seperator oil inlet.Open the bottom valve on the funnel and allow water to flow into the seperator.The water seal is now established.
·         Close the funnel valve and remove the funnel. 
·         Turn the Start/Stop button for pump to the start ‘’Start’’ position and hold it there for 15 to 20 seconds.This will ensure that the pump has the started and the process liquid entering the seperator.The pump indicator lamp lights up.
·         Turn the Start/Stop button for seperating sequance to the ‘’Start’’position.The seperating sequance starts and the seperator reaches full speed after about 20 seconds.
·         Set the counter pressure in the oil outlet linet 50-100 kPa(0,5-1,0 bar)After 60 seconds ,check that oil is not leaving the seperator through the water outlet down to the connecting tank.If oil is escaping in this way,follow the instructions given in the ‘’Trouble Shooting’’chapter in the seperator manual.

Stop to the system;
·         Stop the feed pump by turning the Start/Stop button for pump to the ‘’0’’position.
·         Stop the seperator by turning the Start/Stop button for seperating sequence to the ‘’0’’position.The seperator stops within two minutes.Make sure the seperator has come to a standstill by opening the hatch at the front and using a torch.Approximately 1 litre oil and water will drain off into the collecting tank as the bowl stops.
·         Turn the main switch to the ‘’0 OFF’’ position.
·         Make sure that the valves on both the feed and the outlet sides of the seperator are closed.Oil can otherwise leak through the seperator and the collecting tank can overflow.