START UP;
Starter;
·
Turn the black and red main switch on the
control cabinet to the ‘’1 ON’’ position.
·
Turn both the start buttons to position ‘’1’’ to
power up the control system.
For purifying only;
·
Close the bottom valve on the funnel,if open,and
fill the funnel with water.
·
When the seperator has reached full speed
connect the funnel to the quick-coupling on the seperator oil inlet.Open the
bottom valve on the funnel and allow water to flow into the seperator.The water
seal is now established.
·
Close the funnel valve and remove the
funnel.
·
Turn the Start/Stop button for pump to the start
‘’Start’’ position and hold it there for 15 to 20 seconds.This will ensure that
the pump has the started and the process liquid entering the seperator.The pump
indicator lamp lights up.
·
Turn the Start/Stop button for seperating
sequance to the ‘’Start’’position.The seperating sequance starts and the
seperator reaches full speed after about 20 seconds.
·
Set the counter pressure in the oil outlet linet
50-100 kPa(0,5-1,0 bar)After 60 seconds ,check that oil is not leaving the
seperator through the water outlet down to the connecting tank.If oil is
escaping in this way,follow the instructions given in the ‘’Trouble
Shooting’’chapter in the seperator manual.
Stop to the system;
·
Stop the feed pump by turning the Start/Stop
button for pump to the ‘’0’’position.
·
Stop the seperator by turning the Start/Stop
button for seperating sequence to the ‘’0’’position.The seperator stops within
two minutes.Make sure the seperator has come to a standstill by opening the
hatch at the front and using a torch.Approximately 1 litre oil and water will
drain off into the collecting tank as the bowl stops.
·
Turn the main switch to the ‘’0 OFF’’ position.
·
Make sure that the valves on both the feed and
the outlet sides of the seperator are closed.Oil can otherwise leak through the
seperator and the collecting tank can overflow.